| Medium | Dry compressed air |
| Pressure type | Gauge pressure |
| Pressure unit | bar |
| Measuring range | 0 bar … 10 bar |
| Overpressure safety | 15 bar |
| Process temperature | 0 °C … +60 °C |
| Analog signal output and ohmic load RA |
Optional, 4 mA … 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V Load resistance for current output < 600 Ohm Load resistance with current output > 3 kOhm |
| Zero point adjustment | Max. + 5 % of span |
| Output signal | 2 x PNP/NPN/Push-Pull |
| Diagnostics output | Switching output 2 can be set as diagnostics output |
| Display |
LCD with LED backlight (green/red), can be rotated electronically by 180° Pressure display: 4 digits, 16 segments Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg Update: 1,000, 500, 200, 100 ms (adjustable) |
| Initialization time | 300 ms |
| Process connection | PIF 4 mm + G ¼ 1) |
| Housing material | Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR |
| Connection type | M12 round connector x 1, 4-pin |
| Supply voltage | 17 V DC … 30 V DC |
| Power consumption | Max. 40 mA at L+ = 24 VDC |
| Electrical safety |
Protection class: III Overvoltage protection: 32 V DC Short-circuit protection: QA, Q1, Q2 towards M and L+ Reverse polarity protection: L+ to M |
| CE-conformity | EMC directive: 2004/108/EC, EN 61326-2-3 |
| Weight sensor | Approx. 40 g |
| Enclosure rating | IP65 / IP67 (according to IEC 60529) 2) |
| Protection class III | ✔ |
| RoHS certificate | ✔ |
| CRUus certificate | ✔ |
| MTTF | 261.31 years |