Canadian Owned & Operated For Over 7 Years!

Call us: (647) 250-7307

|

Super Fast Shipping to US & Canada Starting at $7.00 with 3-4 Day Delivery, Faster Options Available!

Techno-tek Full-Alpha

Techno-Tek.com

Additional information

Weight 1.50 lbs
Dimensions 15 × 15 × 8 cm
Brand

Noshok

Manufacturer Part Number

1000-600-2-1-RCP

Country/Region of Manufacture

Germany

MPN

1000-600-2-1-RCP

Model

1000-600-2-1-RCP

Condition Used
Notes This product is used and in good condition 7.5/10. Not in original Packaging.

Noshok 1000-600-2-1-RCP Digital Pressure Gauge with Peak Memory

SKU 115866408843 Category

$749.99 CAD

1 in stock

DESCRIPTION

This product is used. 

Type

Digital Pressure Gauge

Series

1000

Connection Type

Male National Pipe Thread (MNPT)

Case Material

Stainless Steel

Storage Temperature [Min]

-20 ºC-4 ºF

Storage Temperature [Max]

70 ºC158 ºF

Connection Size

1/4 in

Display

Liquid Crystal Display with 0.43″ digits, 4 digits up to 9999 with bar graph

Connection Material

316 Stainless Steel

Gauge Size

3.31 in

Rotatable Base Angle

300 º

Compensated Temperature Range

32 to 140 ºF0 to 60 ºC

Media Temperature Range

-22 to 185 ºF-30 to 85 ºC

Ambient Temperature Range

14 to 140 ºF-10 to 60 ºC

Note for Temperature Range

Effect ±0.15 % per 10K at zero and span, Span effect is ±0.005 % full scale/ºF

Pressure Range

0 to 1,000 psig

Measuring Element

Stainless Steel, Thin-Film Measuring Element

Triangular Bezel Material

Stainless Steel
Power Requirement1 2 x 1.5V “AA” Battery, 4,000 hrs (“AA” 2,000 mAh)

Response Time

200 ms
Proof Pressure [Max]2 15,000 psi

Programmable Functions

Adjustable Through Front Key Pad

Measuring Units

Bar, Psi, MPa

Peak Memory

Min/Max, Display, Hold

Environmental Rating

Ingress Protection (IP65)

Terminal Point Accuracy (±)

0.5 %

Digit Accuracy (±)

1 %

Weight

0.88 lb

Electromagnetic Rating

European Conformity (CE) Compliant to Electromagnetic Compatibility (EMC) Norm European Standards (EN) 61326:2014/A1:1998, Radio Frequency Interference (RFI), Electromagnetic Interference (EMI) and Electrostatic Discharge (ESD) Protection