Canadian Owned & Operated For Over 7 Years!

Super Fast Shipping to US & Canada Starting at $7.00 with 3-4 Day Delivery, Faster Options Available!

Techno-Tek.com

Additional information

Weight 0.18 lbs
Custom Bundle
Modified Item
Brand

Sick

Model

PAC50-DCA

MPN

PAC50-DCA

Condition Used
Notes You Will Receive EXACTLY what is shown in the images ! This product is used and in very good condition 8/10. May not come in original Packaging, is Disinfected&Cleaned for your safety.

SICK, Inc. Pressure sensors PAC50 , PAC50-DCA , 145.0PSI , Female – 1/4" NPT

SKU 115362585685 Category

$141.00

1 in stock

Medium Dry compressed air
Pressure type Gauge pressure
Pressure unit bar
Measuring range 0 bar … 10 bar
Overpressure safety 15 bar
Process temperature 0 °C … +60 °C
Analog signal output and ohmic load RA

Optional, 4 mA … 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V

Load resistance for current output < 600 Ohm

Load resistance with current output > 3 kOhm

Zero point adjustment Max. + 5 % of span
Output signal 2 x PNP/NPN/Push-Pull
Diagnostics output Switching output 2 can be set as diagnostics output
Display

LCD with LED backlight (green/red), can be rotated electronically by 180°

Pressure display: 4 digits, 16 segments

Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg

Update: 1,000, 500, 200, 100 ms (adjustable)

Initialization time 300 ms
Process connection PIF 4 mm + G ¼ 1)
Housing material Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
Connection type M12 round connector x 1, 4-pin
Supply voltage 17 V DC … 30 V DC
Power consumption Max. 40 mA at L+ = 24 VDC
Electrical safety

Protection class: III

Overvoltage protection: 32 V DC

Short-circuit protection: QA, Q1, Q2 towards M and L+

Reverse polarity protection: L+ to M

CE-conformity EMC directive: 2004/108/EC, EN 61326-2-3
Weight sensor Approx. 40 g
Enclosure rating IP65 / IP67 (according to IEC 60529) 2)
Protection class III
RoHS certificate
CRUus certificate
MTTF 261.31 years

  • Non-linearity ≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
    Accuracy ≤ ± 1.5 % of the span
    Setting accuracy of switching outputs ≤ ± 0.2 % of span
    Non-repeatability ≤ ± 0.2 % of the span
    Rated temperature range +10 °C … +60 °C
  • Ambient data
    Ambient temperature 0 °C … +60 °C
    Storage temperature –20 °C … +80 °C
    Relative humidity ≤ 90 %
    Shock load Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
    Vibration load Max. 5 g (10 … 150 Hz), xyz, to DIN EN 60068-2-6